Recruitment to Inflation Ratio

Characterize lung recruitability to personalize PEEP. Adapted from an algorithm developed by The Toronto Centre of Excellence in Mechanical Ventilation (CoEMV).

Recruitment to Inflation Ratio Calculator

Recruitment to Inflation Ratio Calculator

Adapted from an algorithm developed by The Toronto Centre of Excellence in Mechanical Ventilation (CoEMV).

Input Parameters (from a PEEP step maneuver)

Please enter a valid positive number.

Please enter a valid positive number.

Please enter a valid positive number.

Please enter a valid positive number.

Please enter a valid positive number.

Please enter a valid positive number.

Please enter a valid positive number.

Recruitment to Inflation Ratio (R/I):

Interpretation:

Please provide valid positive numbers for all inputs. Ensure Pplatlow > PEEPlow and Vt,current > 0.
Formula Used:

1. Static Compliance at PEEPlow (Clow) = Vlow / (Pplatlow – PEEPlow)
2. Recruited Volume ($\Delta$Vrec) = (Vhigh – Vlow) – Clow $\times$ (Pplathigh – Pplatlow)
3. Recruitment to Inflation Ratio (R/I) = $\Delta$Vrec / Vt,current

Interpretation of R/I Ratio:
  • R/I > 0.5: Suggests high lung recruitability.
  • R/I ≤ 0.5: Suggests low lung recruitability.

Note: This calculator is a clinical decision support tool and should be used by trained healthcare professionals in conjunction with comprehensive patient assessment.